Search results for "CMOS sensor"

showing 10 items of 35 documents

Measuring trunk orientation with a CMOS camera: feasibility and accuracy.

2007

International audience; The purpose of this study was to develop and validate a new tool to objectively quantify trunk orientation at the bedside, especially dedicated to the measurement of the lateropulsion in acute and subacute stroke patients. We developed software to analyze 2D movement with a CMOS camera (Logitech Quickcam Pro 4000) and to calculate the orientation of a segment defined by two color markers. First, the accuracy, reproducibility and noise when measuring segment orientations were evaluated with the CMOS camera placed in different positions, and second trunk orientation was measured in static and in dynamic conditions both with a CMOS camera and with a gold standard 3D vid…

030506 rehabilitationMESH : StrokeComputer scienceMESH: Videotape RecordingMESH : ThoraxSignal[ SDV.NEU.SC ] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Cognitive Sciences0302 clinical medicineImage Processing Computer-AssistedOrthopedics and Sports MedicineComputer visionMESH : AlgorithmsCMOS sensorOrientation (computer vision)Noise (signal processing)Rehabilitation[SDV.NEU.SC]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Cognitive SciencesMESH: PostureThoraxMESH: Image Processing Computer-AssistedMESH: Reproducibility of ResultsStrokeMESH : Software0305 other medical scienceMESH : Image Processing Computer-AssistedAlgorithmsMESH : Feasibility StudiesPostureBiophysicsComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage processingMESH: AlgorithmsMESH: StrokeMESH: Thorax03 medical and health sciencesMESH: SoftwareDistortionHumansSimulationMESH : Videotape RecordingMESH: Humansbusiness.industryMESH : Reproducibility of ResultsMESH : HumansMESH : PostureReproducibility of ResultsVideotape RecordingTrunkFeasibility StudiesArtificial intelligencebusinessParallaxMESH: Feasibility Studies030217 neurology & neurosurgerySoftwareGaitposture
researchProduct

Noncontact monitoring of vascular lesion phototherapy efficiency by RGB multispectral imaging.

2013

A prototype low-cost RGB imaging system consisting of a commercial RGB CMOS sensor, RGB light-emitting diode ring light illuminator, and a set of polarizers was designed and tested for mapping the skin erythema index, in order to monitor skin recovery after phototherapy of vascular lesions, such as hemangiomas and telangiectasias. The contrast of erythema index (CEI) was proposed as a parameter for quantitative characterization of vascular lesions. Skin recovery was characterized as a decrease of the CEI value relative to the value before the treatment. This approach was clinically validated by examining 31 vascular lesions before and after phototherapy.

AdultDiagnostic ImagingSkin erythemaPathologymedicine.medical_specialtyErythemaMultispectral imageBiomedical EngineeringBiomaterialsYoung AdultMedicineHumansTelangiectasisSkinCMOS sensorintegumentary systembusiness.industrySpectrum AnalysisVascular lesionMiddle AgedPhototherapyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsTreatment OutcomeErythemaRGB color modelmedicine.symptombusinessHemangiomaBiomedical engineeringJournal of biomedical optics
researchProduct

A low power interface circuit design for a CMOS based smart optical sensor

2012

In this paper, a CMOS interface circuit as part of an optical sensor-based microsystem for pH monitoring applications is presented. The proposed circuit is capable of processing a voltage signal produced by the light transducer and generating 8-bit digital outputs representing the color information (i.e. wavelength). A resolution of 8 different colors has been achieved as a proof of concept and can easily be extended to a higher number of colors without a major modification in the architecture. The proposed interface circuit is a mixed-signal solution that consists of analog as well as digital building blocks along with a light transducer. It can be used as a portable and non-intrusive opti…

CMOS sensorEngineeringTransducerIntelligent sensorCMOSbusiness.industryCircuit designMicrosystemInterface (computing)Electrical engineeringElectronic engineeringbusinessSignal2012 IEEE International Conference on Circuits and Systems (ICCAS)
researchProduct

ALICE forward rapidity upgrades

2017

Two forward rapidity upgrades of the ALICE apparatus at the LHC are presented: the Muon Forward Tracker (MFT) and the Fast Interaction Trigger (FIT). Their designs are driven by physics performance studies, which have been done using MC simulations. Several prototypes have been tested. Currently the detector design phase has ended. The final layouts, geometries and expected performance figures are presented. The latest developments from the test of the prototypes are discussed. The MFT will improve the performance of the ALICE Muon Spectrometer by adding vertexing capabilities to the system. The elementary component of the MFT is a Monolithic Active Pixel Sensor (MAPS), using the TowerJazz …

CMOS sensorLarge Hadron ColliderMuon Forward TrackerInteraction pointta114Computer sciencebusiness.industryCherenkov detectorFast Interaction TriggerPhysics::Instrumentation and DetectorsMonte Carlo methodDetectorALICE apparatuslaw.inventionOpticslawMicrochannel plate detectorDetectors and Experimental TechniquesbusinessCherenkov radiation
researchProduct

Update on the TowerJazz CMOS DMAPS development for the ATLAS ITk

2019

The upgrade of the ATLAS tracking detector for the High-Luminosity Large Hadron Collider at CERN requires the development of novel radiation hard silicon sensor technologies. For the de- velopment of depleted CMOS sensors for ATLAS we combined small electrodes with minimal capacitance and advanced processing for fully depleted active sensor volume to achieve radiation hard CMOS sensors in line with ATLAS ITk specifications. Based on initial studies on the prototype sensor “TowerJazz Investigator” we have now developed, produced and tested a first full-size depleted CMOS sensor based on the 180nm TowerJazz imag- ing process, the so-called “MALTA” sensor. The sensor combines special low-noise…

CMOS sensorLarge Hadron Colliderbusiness.industryComputer sciencePhysics::Instrumentation and DetectorsDetectorElectronic detector readout concepts (solid-state) ; Front-end electronics for detector readout ; Particle tracking detectors ; Radiation-hard detectorsChipCapacitancemedicine.anatomical_structureUpgradeCMOSAtlas (anatomy)medicineComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSDetectors and Experimental TechniquesbusinessComputer hardware
researchProduct

Embedded neural network system for microorganisms growth analysis

2020

This study presents autonomous system for microorganisms’ growth analysis in laboratory environment. As shown in previous research, laser speckle analysis allows detecting submicron changes of substrate with growing bacteria. By using neural networks for speckle analysis, it is possible to develop autonomous system, that can evaluate microorganisms’ growth by using cheap optics and electronics elements. System includes embedded processing module, CMOS camera, 670nm laser diode and optionally WiFi module for connecting to external image storage system. Due to small size, system could be fully placed in laboratory incubator with constant humidity and temperature. By using laser diode, Petri d…

CMOS sensorLaser diodeArtificial neural networkComputer sciencebusiness.industryReal-time computingENCODElaw.inventionSpeckle patternlawComputer data storageElectronicsAutonomous system (mathematics)businessSaratov Fall Meeting 2019: Optical and Nano-Technologies for Biology and Medicine
researchProduct

Multispectral and autofluorescence RGB imaging for skin cancer diagnostics

2019

This paper presents the results of statistical clinical data, combining two diagnostic methods. A combination of two skin imaging methods – diffuse reflectance and autofluorescence – has been applied for skin cancer diagnostics. Autofluorescence (AF) and multispectral diffuse reflectance images were acquired by custom made prototype with 405 nm, 526 nm, 663 nm and 964 nm LEDs and RGB CMOS camera. Parameter p’ was calculated from diffuse reflectance images under green, red and infrared illumination, AF intensity (I’) was calculated from AF images exited at 405nm wavelength. Obtained results show that criterion p` > 1 gives possibility to discriminate melanomas and different kind of keratosis…

CMOS sensorMaterials scienceKeratosisbusiness.industryMultispectral imagemedicine.diseaselaw.inventionAutofluorescenceWavelengthOpticslawmedicineRGB color modelDiffuse reflectionbusinessLight-emitting diodeSaratov Fall Meeting 2018: Optical and Nano-Technologies for Biology and Medicine
researchProduct

RGB imaging system for monitoring of skin vascular malformation's laser therapy

2012

A prototype RGB imaging system for mapping of skin chromophores consists of a commercial RGB CMOS sensor, RGB LEDs ring-light illuminator and orthogonally orientated polarizers for reducing specular reflectance. The system was used for monitoring of vascular malformations (hemagiomas and telangiectasias) therapy.

CMOS sensorMaterials sciencebusiness.industryVascular malformationPolarizermedicine.diseaseReflectivitylaw.inventionOpticsLaser therapylawmedicineOptoelectronicsRGB color modelSpecular reflectionbusinessLight-emitting diodeSPIE Proceedings
researchProduct

Multimodal device for assessment of skin malformations

2013

A variety of multi-spectral imaging devices is commercially available and used for skin diagnostics and monitoring; however, an alternative cost-efficient device can provide an advanced spectral analysis of skin. A compact multimodal device for diagnosis of pigmented skin lesions was developed and tested. A polarized LED light source illuminates the skin surface at four different wavelengths – blue (450 nm), green (545 nm), red (660 nm) and infrared (940 nm). Spectra of reflected light from the 25 mm wide skin spot are imaged by a CMOS sensor. Four spectral images are obtained for mapping of the main skin chromophores. The specific chromophore distribution differences between different skin…

CMOS sensorMedical diagnosticMaterials scienceintegumentary systembusiness.industryInfraredMultispectral imageOpticsLight sourceSkin surfaceSpectral analysisPigmented skinbusinessBiomedical engineeringSPIE Proceedings
researchProduct

LASCA and PPG imaging for non-contact assessment of skin blood supply

2013

Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging (LDPI). Photoplethysmography (PPG) is well known technique for assessment of skin blood pulsations that can be related to blood flow. In recent years several studies have been done on development of non-contact PPG imaging (PPGI). LASCA and PPGI techniques are simpler and cheaper compared with LDPI. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new i…

CMOS sensorPixelComputer scienceSkin blood flowbusiness.industryColor imageBlood flowArterial occlusionsymbols.namesakeSpeckle patternOpticsPhotoplethysmogramsymbolsBlood supplybusinessDoppler effectBiomedical engineeringMedical Imaging 2013: Physics of Medical Imaging
researchProduct